BS 970 EN110 vs IS 1570 (Part 7) 10Mo6H

Minimal Match — 35% match based on chemical composition and mechanical property overlap.

BS 970 EN110 (BS 970:1955) and IS 1570 (Part 7) 10Mo6H (IS 1570 (Part 7):1992) are both steel grades. Both fall under the Alloy Steel category. BS 970 EN110 is typically used for bars and billets for forging; forgings and drop-forgings; bars for machining; bright bars. suitable for 50/60 (s), 55/65 (t), 60/70 (u), 65/75 (v), 70/80 (w) tons/sq in according to ruling section. capable of meeting the test requirements of en 16, en 17 and en 19., while IS 1570 (Part 7) 10Mo6H is commonly used for boilers, pressure vessels, steam turbines, steam and water piping and other power plant equipment working at elevated temperature. BS 970 EN110 is defined under British Standards (BS), originating from United Kingdom, while IS 1570 (Part 7) 10Mo6H is defined under Bureau of Indian Standards (IS), originating from India.

As per chemical composition, BS 970 EN110 vs IS 1570 (Part 7) 10Mo6H is a 60% match. As per mechanical properties, the match is 0%. Combined, this makes them a minimal match overall at 35%.

Frequently Compared With BS 970 EN110:
IS 1570 (Part 4) 07Cr4Mo6 IS 4367 07Cr4Mo6 NF A35-565 100C6 UNI 11234 100Cr6 IS 1570 (Part 4) 103Cr4 IS 1570 (Part 4) 103Cr6 IS 1570 (Part 4) 105Cr5 IS 1570 (Part 4) 10Cr20Mo6 IS 1570 (Part 7) 10Cr36Mo10H IS 4367 10Cr9Mo10 EN 10028-2 10CrMo9-10 IS 1570 (Part 4) 10Mo6
Match Breakdown
CHEMISTRY MATCH
60%
MECHANICAL MATCH
0%
OVERALL
35%
Specifications
Property BS 970 EN110 IS 1570 (Part 7) 10Mo6H
Standard BS 970:1955 IS 1570 (Part 7):1992
Category Alloy Steel Alloy Steel
C (%) 0.35-0.45 <=0.15
Si (%) 0.10-0.35 0.50-1.00
Mn (%) 0.40-0.80 0.30-0.60
Ni (%) 1.20-1.60 Not specified
Cr (%) 0.90-1.40 1.00-1.50
Mo (%) 0.10-0.20 0.45-0.60
S (%) <=0.050 <=0.030
P (%) <=0.050 <=0.030
Matched by chemical composition and mechanical properties, not a formal equivalence claim. Always verify against the applicable standard before substitution.
Mechanical Properties
Property BS 970 EN110 IS 1570 (Part 7) 10Mo6H
Tensile Strength ≥772 MPa (50 tons/sq in, converted) >=415 MPa
Yield Strength ≥587 MPa (38 tons/sq in, converted) >=205 MPa (0.2 % proof stress)
Elongation ≥20% >=30%
Hardness 223-277 HB Not specified
Condition Hardened and tempered S, ruling section 6 in (lowest-strength condition of the standard) Tubes, N+T, thickness - (first row of Table 3)
Typical Applications
BS 970 EN110
Bars and billets for forging; forgings and drop-forgings; bars for machining; bright bars. Suitable for 50/60 (S), 55/65 (T), 60/70 (U), 65/75 (V), 70/80 (W) tons/sq in according to ruling section. Capable of meeting the test requirements of En 16, En 17 and En 19.
IS 1570 (Part 7) 10Mo6H
Boilers, pressure vessels, steam turbines, steam and water piping and other power plant equipment working at elevated temperature
Key Differences
Can BS 970 EN110 Be Substituted With IS 1570 (Part 7) 10Mo6H?
BS 970 EN110 and IS 1570 (Part 7) 10Mo6H share some compositional similarity but differ enough that substitution should not be assumed. Review the differences above carefully, and consult the applicable standard or a metallurgist before using one in place of the other.
On M-EX Right Now
BS 970 EN110
0 active listings and RFQs →
IS 1570 (Part 7) 10Mo6H
0 active listings and RFQs →
Frequently Asked Questions
What is the difference between BS 970 EN110 and IS 1570 (Part 7) 10Mo6H?
BS 970 EN110 specifies Ni which is not specified for IS 1570 (Part 7) 10Mo6H.
Can BS 970 EN110 be substituted with IS 1570 (Part 7) 10Mo6H?
BS 970 EN110 and IS 1570 (Part 7) 10Mo6H share some compositional similarity but differ enough that substitution should not be assumed. Review the differences above carefully, and consult the applicable standard or a metallurgist before using one in place of the other.