Strong Match — 94.1% match
based on chemical composition and mechanical property overlap.
BS 970 EN8E (BS 970:1955) and BS 970 EN8 (BS 970:1955) are both steel grades.
Both fall under the Carbon Steel category.
BS 970 EN8E is defined under British Standards (BS), originating from United Kingdom, while BS 970 EN8 is defined under British Standards (BS), originating from United Kingdom.
As per chemical composition, BS 970 EN8E vs BS 970 EN8 is a 91.1% match.
As per mechanical properties, the match is 100%.
Combined, this makes them a strong match overall at 94.1%.
Matched by chemical composition and mechanical properties, not a formal equivalence claim. Always verify against the applicable standard before substitution.
Mechanical Properties
Property
BS 970 EN8E
BS 970 EN8
Tensile Strength
≥541 MPa (35 tons/sq in, converted)
≥541 MPa (35 tons/sq in, converted)
Yield Strength
≥278 MPa (18 tons/sq in, converted)
≥278 MPa (18 tons/sq in, converted)
Elongation
≥20%
≥20%
Hardness
152-207 HB
152-207 HB
Condition
NGC 1, Normalised, ruling section 6 in (lowest-strength condition of the standard)
NGC 1, Normalised, ruling section 6 in (lowest-strength condition of the standard)
Typical Applications
BS 970 EN8E
Not documented
BS 970 EN8
Shafts, gears, studs, keys, general machined parts
Can BS 970 EN8E Be Substituted With BS 970 EN8?
BS 970 EN8E and BS 970 EN8 overlap closely enough on chemistry and mechanical properties that BS 970 EN8 is often considered as a substitute for BS 970 EN8E in many applications. Always confirm the specific property range your application needs before substituting, and check with your supplier's mill certificate.
What is the difference between BS 970 EN8E and BS 970 EN8?
Both grades share a similar composition profile; see the specification table above for the exact chemistry and mechanical property values.
Can BS 970 EN8E be substituted with BS 970 EN8?
BS 970 EN8E and BS 970 EN8 overlap closely enough on chemistry and mechanical properties that BS 970 EN8 is often considered as a substitute for BS 970 EN8E in many applications. Always confirm the specific property range your application needs before substituting, and check with your supplier's mill certificate.