EN 10025-2 S275J2 vs CSA G40.21 480W

Related Material — 59.5% match based on chemical composition and mechanical property overlap.

EN 10025-2 S275J2 (EN 10025-2:2019) and CSA G40.21 480W (CSA G40.21-13 (R2023)) are both steel grades. Both fall under the Structural Steel category. EN 10025-2 S275J2 is typically used for hot rolled products of structural steels, while CSA G40.21 480W is commonly used for heavy cranes, offshore structures, high-rise building frames, pressure vessels, heavy mining equipment.. EN 10025-2 S275J2 is defined under European Standard (EN), originating from Europe, while CSA G40.21 480W is defined under Canadian Standards Association (CSA), originating from Canada.

As per chemical composition, EN 10025-2 S275J2 vs CSA G40.21 480W is a 89.2% match. As per mechanical properties, the match is 0%. Combined, this makes them a related material overall at 59.5%.

Frequently Compared With EN 10025-2 S275J2:
ASTM A1008 SS Grade 50 GOST 19281 09G2S CSA G40.21 260W AS/NZS 3679.1 300 AS/NZS 3679.1 350 CSA G40.21 350W CSA G40.21 400A ASTM A1008 SS Grade 80 ASTM A283C ASTM A572 Gr.65
Other Structural Steel Grades to Compare With EN 10025-2 S275J2:
CSA G40.21 300W CSA G40.21 400W
Match Breakdown
CHEMISTRY MATCH
89.2%
MECHANICAL MATCH
0%
OVERALL
59.5%
Specifications
Property EN 10025-2 S275J2 CSA G40.21 480W
Standard EN 10025-2:2019 CSA G40.21-13 (R2023)
Category Structural Steel Structural Steel
C (%) <=0.21 max 0.23
Mn (%) <=1.50 max 1.7
P (%) <=0.025 max 0.035
S (%) <=0.025 max 0.035
Cu (%) <=0.55 Not specified
Si (%) Not specified max 0.5
Matched by chemical composition and mechanical properties, not a formal equivalence claim. Always verify against the applicable standard before substitution.
Mechanical Properties
Property EN 10025-2 S275J2 CSA G40.21 480W
Tensile Strength 410-560 MPa 590-790 MPa
Yield Strength >=275 MPa 480 MPa min
Elongation >=23% Not specified
Condition Nominal thickness up to 16 mm (tensile for 3 to 100 mm, elongation for 3 to 40 mm), longitudinal test pieces Not specified
Typical Applications
EN 10025-2 S275J2
Hot rolled products of structural steels
CSA G40.21 480W
Heavy cranes, offshore structures, high-rise building frames, pressure vessels, heavy mining equipment.
Key Differences
Can EN 10025-2 S275J2 Be Substituted With CSA G40.21 480W?
EN 10025-2 S275J2 and CSA G40.21 480W share some compositional similarity but differ enough that substitution should not be assumed. Review the differences above carefully, and consult the applicable standard or a metallurgist before using one in place of the other.
Forms & Sizes Available on M-EX
EN 10025-2 S275J2
No active listings currently.
CSA G40.21 480W
Plate → (2 listings)
Thickness: 10–10 mm (0.39–0.39 in)
Width: 1500–1500 mm (59.06–59.06 in)
Length: 2900–3000 mm (114.17–118.11 in)
On M-EX Right Now
EN 10025-2 S275J2
0 active listings and RFQs →
CSA G40.21 480W
2 active listings and RFQs →
Frequently Asked Questions
What is the difference between EN 10025-2 S275J2 and CSA G40.21 480W?
EN 10025-2 S275J2 specifies Cu which is not specified for CSA G40.21 480W. CSA G40.21 480W specifies Si which is not specified for EN 10025-2 S275J2.
Can EN 10025-2 S275J2 be substituted with CSA G40.21 480W?
EN 10025-2 S275J2 and CSA G40.21 480W share some compositional similarity but differ enough that substitution should not be assumed. Review the differences above carefully, and consult the applicable standard or a metallurgist before using one in place of the other.