IS 11169 (Part 2) X12Cr12 vs EN 10088-1 1.4301

Minimal Match — 35% match based on chemical composition and mechanical property overlap.

IS 11169 (Part 2) X12Cr12 (IS 11169 (Part 2):1989) and EN 10088-1 1.4301 (EN 10088-1:2014) are both steel grades. Both fall under the Stainless Steel category. IS 11169 (Part 2) X12Cr12 is typically used for cold heading and cold extrusion; the standard covers wires, wire rods and bars (clause 1.1), while EN 10088-1 1.4301 is commonly used for food equipment, chemical vessels, architectural, kitchenware. IS 11169 (Part 2) X12Cr12 is defined under Bureau of Indian Standards (IS), originating from India, while EN 10088-1 1.4301 is defined under European Standard (EN), originating from Europe.

As per chemical composition, IS 11169 (Part 2) X12Cr12 vs EN 10088-1 1.4301 is a 63.1% match. As per mechanical properties, the match is 0%. Combined, this makes them a minimal match overall at 35%.

Frequently Compared With IS 11169 (Part 2) X12Cr12:
GB/T 3280 06Cr19Ni10 GOST 5632 06Kh23N28 EN 10088-1 1.4006 EN 10088-1 1.4401 IS 1570 (Part 7) 11Cr17Ni13W3TiH GOST 5632 12Kh13 EN 10088-1 1.4845 IS 1570 (Part 7) 12Cr12MoH IS 1570 (Part 7) 12Cr12MoVH IS 1570 (Part 7) 12Cr13H GOST 5632 08X18H10 IS 1570 (Part 7) 12Cr12Ni2Mo
Match Breakdown
CHEMISTRY MATCH
63.1%
MECHANICAL MATCH
0%
OVERALL
35%
Specifications
Property IS 11169 (Part 2) X12Cr12 EN 10088-1 1.4301
Standard IS 11169 (Part 2):1989 EN 10088-1:2014
Category Stainless Steel Stainless Steel
C (%) 0.08-0.15 ≤0.07
Si (%) <=1.0 ≤1.00
Mn (%) <=1.0 ≤2.00
Cr (%) 11.5-13.5 17.5–19.5
S (%) <=0.030 ≤0.030
P (%) <=0.045 ≤0.045
Ni (%) Not specified 8.0–10.5
Matched by chemical composition and mechanical properties, not a formal equivalence claim. Always verify against the applicable standard before substitution.
Mechanical Properties
Property IS 11169 (Part 2) X12Cr12 EN 10088-1 1.4301
Yield Strength (0.2% proof) >=450 MPa Not specified
Tensile Strength 600-750 MPa ≥520 MPa
Elongation >=18% ≥45%
Impact (U-notch 5 mm) >=50 J Not specified
Condition Quenched and tempered reference test piece (Table 6 treatment) Not specified
Yield Strength Not specified ≥210 MPa
Hardness Not specified ≤215 HB
Typical Applications
IS 11169 (Part 2) X12Cr12
Cold heading and cold extrusion; the standard covers wires, wire rods and bars (clause 1.1)
EN 10088-1 1.4301
Food equipment, chemical vessels, architectural, kitchenware
Key Differences
Can IS 11169 (Part 2) X12Cr12 Be Substituted With EN 10088-1 1.4301?
IS 11169 (Part 2) X12Cr12 and EN 10088-1 1.4301 share some compositional similarity but differ enough that substitution should not be assumed. Review the differences above carefully, and consult the applicable standard or a metallurgist before using one in place of the other.
Forms & Sizes Available on M-EX
IS 11169 (Part 2) X12Cr12
No active listings currently.
EN 10088-1 1.4301
Sheet → (3 listings)
Thickness: 6–6 mm (0.24–0.24 in)
Width: 1250–1250 mm (49.21–49.21 in)
Length: 2500–3300 mm (98.43–129.92 in)
On M-EX Right Now
IS 11169 (Part 2) X12Cr12
0 active listings and RFQs →
EN 10088-1 1.4301
3 active listings and RFQs →
Frequently Asked Questions
What is the difference between IS 11169 (Part 2) X12Cr12 and EN 10088-1 1.4301?
EN 10088-1 1.4301 specifies Ni which is not specified for IS 11169 (Part 2) X12Cr12.
Can IS 11169 (Part 2) X12Cr12 be substituted with EN 10088-1 1.4301?
IS 11169 (Part 2) X12Cr12 and EN 10088-1 1.4301 share some compositional similarity but differ enough that substitution should not be assumed. Review the differences above carefully, and consult the applicable standard or a metallurgist before using one in place of the other.