Strong Match — 94.3% match
based on chemical composition and mechanical property overlap.
IS 1570 (Part 2/Sec 1) 75C6 (IS 1570 (Part 2/Sec 1):1979) and DIN 17222 C75 (DIN 17222:1979-08) are both steel grades.
Both fall under the Carbon Steel category.
IS 1570 (Part 2/Sec 1) 75C6 is typically used for cold rolled strip for springs and railway laminated springs (the standard links this grade to is 2507, is 3885), while DIN 17222 C75 is commonly used for springs, chisels, punches, cutting tools, hand tools.
IS 1570 (Part 2/Sec 1) 75C6 is defined under Bureau of Indian Standards (IS), originating from India, while DIN 17222 C75 is defined under Deutsches Institut fur Normung (DIN), originating from Germany.
As per chemical composition, IS 1570 (Part 2/Sec 1) 75C6 vs DIN 17222 C75 is a 94.3% match.
Mechanical property data is not available for both grades, so this factor could not be scored.
Combined, this makes them a strong match overall at 94.3%.
Frequently Compared With IS 1570 (Part 2/Sec 1) 75C6:
Matched by chemical composition and mechanical properties, not a formal equivalence claim. Always verify against the applicable standard before substitution.
Mechanical Properties
Property
IS 1570 (Part 2/Sec 1) 75C6
DIN 17222 C75
Tensile Strength
Not specified
850–1000 MPa (annealed)
Hardness HRC
Not specified
58–63 (hardened)
Hardness HB
Not specified
229–285 (annealed)
Typical Applications
IS 1570 (Part 2/Sec 1) 75C6
Cold rolled strip for springs and railway laminated springs (the standard links this grade to IS 2507, IS 3885)
DIN 17222 C75
Springs, chisels, punches, cutting tools, hand tools
Key Differences
DIN 17222 C75 specifies Si, S, P which are not specified for IS 1570 (Part 2/Sec 1) 75C6.
Can IS 1570 (Part 2/Sec 1) 75C6 Be Substituted With DIN 17222 C75?
IS 1570 (Part 2/Sec 1) 75C6 and DIN 17222 C75 overlap closely enough on chemistry and mechanical properties that DIN 17222 C75 is often considered as a substitute for IS 1570 (Part 2/Sec 1) 75C6 in many applications. Always confirm the specific property range your application needs before substituting, and check with your supplier's mill certificate.
What is the difference between IS 1570 (Part 2/Sec 1) 75C6 and DIN 17222 C75?
DIN 17222 C75 specifies Si, S, P which are not specified for IS 1570 (Part 2/Sec 1) 75C6.
Can IS 1570 (Part 2/Sec 1) 75C6 be substituted with DIN 17222 C75?
IS 1570 (Part 2/Sec 1) 75C6 and DIN 17222 C75 overlap closely enough on chemistry and mechanical properties that DIN 17222 C75 is often considered as a substitute for IS 1570 (Part 2/Sec 1) 75C6 in many applications. Always confirm the specific property range your application needs before substituting, and check with your supplier's mill certificate.