IS 1570 (Part 4) 15Ni7Cr4Mo2 vs IS 11169 (Part 1) 15Ni7Cr4Mo2
Strong Match — 95.2% match
based on chemical composition and mechanical property overlap.
IS 1570 (Part 4) 15Ni7Cr4Mo2 (IS 1570 (Part 4):1988) and IS 11169 (Part 1) 15Ni7Cr4Mo2 (IS 11169 (Part 1):2022) are both steel grades.
Both fall under the Alloy Steel category.
IS 1570 (Part 4) 15Ni7Cr4Mo2 is defined under Bureau of Indian Standards (IS), originating from India, while IS 11169 (Part 1) 15Ni7Cr4Mo2 is defined under Bureau of Indian Standards (IS), originating from India.
As per chemical composition, IS 1570 (Part 4) 15Ni7Cr4Mo2 vs IS 11169 (Part 1) 15Ni7Cr4Mo2 is a 95.2% match.
Mechanical property data is not available for both grades, so this factor could not be scored.
Combined, this makes them a strong match overall at 95.2%.
Frequently Compared With IS 1570 (Part 4) 15Ni7Cr4Mo2:
Matched by chemical composition and mechanical properties, not a formal equivalence claim. Always verify against the applicable standard before substitution.
Mechanical Properties
Property
IS 1570 (Part 4) 15Ni7Cr4Mo2
IS 11169 (Part 1) 15Ni7Cr4Mo2
Tensile Strength
>=1080 MPa
Not specified
Elongation
>=9%
Not specified
Izod Impact
>=35 J
Not specified
Condition
Case hardening steel, refined and quenched, core properties
Not specified
Hardness, annealed (+AC)
Not specified
<=180 HBW
Typical Applications
IS 1570 (Part 4) 15Ni7Cr4Mo2
Not documented
IS 11169 (Part 1) 15Ni7Cr4Mo2
Cold heading and cold extrusion of parts that are case hardened; the standard covers bars, wire rods and wires of 2 to 100 mm (clause 1.1, Annex B)
Key Differences
IS 11169 (Part 1) 15Ni7Cr4Mo2 specifies Cu, P, S which are not specified for IS 1570 (Part 4) 15Ni7Cr4Mo2.
Can IS 1570 (Part 4) 15Ni7Cr4Mo2 Be Substituted With IS 11169 (Part 1) 15Ni7Cr4Mo2?
IS 1570 (Part 4) 15Ni7Cr4Mo2 and IS 11169 (Part 1) 15Ni7Cr4Mo2 overlap closely enough on chemistry and mechanical properties that IS 11169 (Part 1) 15Ni7Cr4Mo2 is often considered as a substitute for IS 1570 (Part 4) 15Ni7Cr4Mo2 in many applications. Always confirm the specific property range your application needs before substituting, and check with your supplier's mill certificate.
What is the difference between IS 1570 (Part 4) 15Ni7Cr4Mo2 and IS 11169 (Part 1) 15Ni7Cr4Mo2?
IS 11169 (Part 1) 15Ni7Cr4Mo2 specifies Cu, P, S which are not specified for IS 1570 (Part 4) 15Ni7Cr4Mo2.
Can IS 1570 (Part 4) 15Ni7Cr4Mo2 be substituted with IS 11169 (Part 1) 15Ni7Cr4Mo2?
IS 1570 (Part 4) 15Ni7Cr4Mo2 and IS 11169 (Part 1) 15Ni7Cr4Mo2 overlap closely enough on chemistry and mechanical properties that IS 11169 (Part 1) 15Ni7Cr4Mo2 is often considered as a substitute for IS 1570 (Part 4) 15Ni7Cr4Mo2 in many applications. Always confirm the specific property range your application needs before substituting, and check with your supplier's mill certificate.