IS 5522 X04Cr19Ni9 vs IS 1570 (Part 7) 12Cr13H

Minimal Match — 45.2% match based on chemical composition and mechanical property overlap.

IS 5522 X04Cr19Ni9 (IS 5522:2014) and IS 1570 (Part 7) 12Cr13H (IS 1570 (Part 7):1992) are both steel grades. Both fall under the Stainless Steel category. IS 5522 X04Cr19Ni9 is typically used for utensils, while IS 1570 (Part 7) 12Cr13H is commonly used for boilers, pressure vessels, steam turbines, steam and water piping and other power plant equipment working at elevated temperature. IS 5522 X04Cr19Ni9 is defined under Bureau of Indian Standards (IS), originating from India, while IS 1570 (Part 7) 12Cr13H is defined under Bureau of Indian Standards (IS), originating from India.

As per chemical composition, IS 5522 X04Cr19Ni9 vs IS 1570 (Part 7) 12Cr13H is a 67.7% match. As per mechanical properties, the match is 0%. Combined, this makes them a minimal match overall at 45.2%.

Frequently Compared With IS 5522 X04Cr19Ni9:
GB/T 3280 06Cr19Ni10 ASTM A959 .- GOST 5632 08X18H10 EN 10088-1 1.4006 EN 10088-1 1.4401 IS 1570 (Part 7) 12Cr12MoH IS 1570 (Part 7) 12Cr12Ni2Mo GOST 5632 06Kh23N28 EN 10088-1 1.4301 EN 10088-1 1.4845 IS 1570 (Part 7) 11Cr17Ni13W3TiH IS 1570 (Part 7) 12Cr12MoVH
Match Breakdown
CHEMISTRY MATCH
67.7%
MECHANICAL MATCH
0%
OVERALL
45.2%
Specifications
Property IS 5522 X04Cr19Ni9 IS 1570 (Part 7) 12Cr13H
Standard IS 5522:2014 IS 1570 (Part 7):1992
Category Stainless Steel Stainless Steel
C (%) <=0.07 0.09-0.15
Si (%) <=0.75 <=1.00
Mn (%) <=2.00 <=1.00
Ni (%) 8.0-10.5 <=1.00
Cr (%) 17.5-19.5 11.5-14.00
S (%) <=0.030 <=0.030
P (%) <=0.045 <=0.040
N (%) <=0.10 Not specified
Matched by chemical composition and mechanical properties, not a formal equivalence claim. Always verify against the applicable standard before substitution.
Mechanical Properties
Property IS 5522 X04Cr19Ni9 IS 1570 (Part 7) 12Cr13H
Tensile Strength >=515 MPa 470-670 MPa
Yield Strength >=205 MPa >=265 MPa (0.2 % proof stress)
Elongation >=40% >=20%
Hardness <=201 HB Not specified
Condition Annealed/softened Bars, forgings, plates, A, thickness up to 160 (first row of Table 3)
Typical Applications
IS 5522 X04Cr19Ni9
Utensils
IS 1570 (Part 7) 12Cr13H
Boilers, pressure vessels, steam turbines, steam and water piping and other power plant equipment working at elevated temperature
Key Differences
Can IS 5522 X04Cr19Ni9 Be Substituted With IS 1570 (Part 7) 12Cr13H?
IS 5522 X04Cr19Ni9 and IS 1570 (Part 7) 12Cr13H share some compositional similarity but differ enough that substitution should not be assumed. Review the differences above carefully, and consult the applicable standard or a metallurgist before using one in place of the other.
On M-EX Right Now
IS 5522 X04Cr19Ni9
0 active listings and RFQs →
IS 1570 (Part 7) 12Cr13H
0 active listings and RFQs →
Frequently Asked Questions
What is the difference between IS 5522 X04Cr19Ni9 and IS 1570 (Part 7) 12Cr13H?
IS 5522 X04Cr19Ni9 specifies N which is not specified for IS 1570 (Part 7) 12Cr13H.
Can IS 5522 X04Cr19Ni9 be substituted with IS 1570 (Part 7) 12Cr13H?
IS 5522 X04Cr19Ni9 and IS 1570 (Part 7) 12Cr13H share some compositional similarity but differ enough that substitution should not be assumed. Review the differences above carefully, and consult the applicable standard or a metallurgist before using one in place of the other.