AS/NZS 3679.1 350 vs CSA G40.21 260W

Close Alternative — 72.5% match based on chemical composition and mechanical property overlap.

AS/NZS 3679.1 350 (AS/NZS 3679.1:2016) and CSA G40.21 260W (CSA G40.21-13 (R2023)) are both steel grades. Both fall under the Structural Steel category. AS/NZS 3679.1 350 is typically used for hot-rolled structural bars and sections for primary structural beams, columns, and framing, while CSA G40.21 260W is commonly used for bridges, buildings, general structural fabrication, storage tanks, older infrastructure projects.. AS/NZS 3679.1 350 is defined under Australian/New Zealand Standard (AS/NZS), originating from Australia/New Zealand, while CSA G40.21 260W is defined under Canadian Standards Association (CSA), originating from Canada.

As per chemical composition, AS/NZS 3679.1 350 vs CSA G40.21 260W is a 96.8% match. As per mechanical properties, the match is 23.9%. Combined, this makes them a close alternative overall at 72.5%.

Frequently Compared With AS/NZS 3679.1 350:
CSA G40.21 480W CSA G40.21 350W CSA G40.21 400W AS/NZS 1595 C450 ASTM A1008 SS Grade 50 IS 2062 E250B0 ASTM A1008 SS Grade 80 AS/NZS 1595 C350 ASTM A572 Grade 50 IS 2062 E250A ASTM A283C ASTM A572 Gr.65
Match Breakdown
CHEMISTRY MATCH
96.8%
MECHANICAL MATCH
23.9%
OVERALL
72.5%
Specifications
Property AS/NZS 3679.1 350 CSA G40.21 260W
Standard AS/NZS 3679.1:2016 CSA G40.21-13 (R2023)
Category Structural Steel Structural Steel
C (%) <=0.22 max 0.23
Mn (%) <=1.70 max 1.4
Si (%) <=0.50 max 0.4
P (%) <=0.040 max 0.035
S (%) <=0.040 max 0.035
Matched by chemical composition and mechanical properties, not a formal equivalence claim. Always verify against the applicable standard before substitution.
Mechanical Properties
Property AS/NZS 3679.1 350 CSA G40.21 260W
Tensile Strength 480-640 MPa 410-590 MPa
Yield Strength 350 MPa min 260 MPa min
Elongation 20% min Not specified
Typical Applications
AS/NZS 3679.1 350
Hot-rolled structural bars and sections for primary structural beams, columns, and framing
CSA G40.21 260W
Bridges, buildings, general structural fabrication, storage tanks, older infrastructure projects.
Can AS/NZS 3679.1 350 Be Substituted With CSA G40.21 260W?
AS/NZS 3679.1 350 and CSA G40.21 260W are a close alternative rather than a direct substitute. Some properties overlap well, but check the specific chemistry and mechanical rows above against your application's requirements before treating them as interchangeable.
Forms & Sizes Available on M-EX
AS/NZS 3679.1 350
Plate → (2 listings)
Thickness: 10–10 mm (0.39–0.39 in)
Width: 1500–1500 mm (59.06–59.06 in)
Length: 2900–3200 mm (114.17–125.98 in)
CSA G40.21 260W
Plate → (2 listings)
Thickness: 10–10 mm (0.39–0.39 in)
Width: 1500–1500 mm (59.06–59.06 in)
Length: 3400–4000 mm (133.86–157.48 in)
On M-EX Right Now
AS/NZS 3679.1 350
2 active listings and RFQs →
CSA G40.21 260W
2 active listings and RFQs →
Frequently Asked Questions
What is the difference between AS/NZS 3679.1 350 and CSA G40.21 260W?
Both grades share a similar composition profile; see the specification table above for the exact chemistry and mechanical property values.
Can AS/NZS 3679.1 350 be substituted with CSA G40.21 260W?
AS/NZS 3679.1 350 and CSA G40.21 260W are a close alternative rather than a direct substitute. Some properties overlap well, but check the specific chemistry and mechanical rows above against your application's requirements before treating them as interchangeable.