Related Material — 55.5% match
based on chemical composition and mechanical property overlap.
BS 970 EN3B (BS 970:1955) and BS 970 (Part 1) 045A10 (BS 970 (Part 1):1991) are both steel grades.
Both fall under the Carbon Steel category.
BS 970 EN3B is typically used for general engineering, cold forming, while BS 970 (Part 1) 045A10 is commonly used for case hardening steel (section four).
BS 970 EN3B is defined under British Standards (BS), originating from United Kingdom, while BS 970 (Part 1) 045A10 is defined under British Standards (BS), originating from United Kingdom.
As per chemical composition, BS 970 EN3B vs BS 970 (Part 1) 045A10 is a 83.3% match.
As per mechanical properties, the match is 0%.
Combined, this makes them a related material overall at 55.5%.
Matched by chemical composition and mechanical properties, not a formal equivalence claim. Always verify against the applicable standard before substitution.
Mechanical Properties
Property
BS 970 EN3B
BS 970 (Part 1) 045A10
Tensile Strength
≥432 MPa (28 tons/sq in, converted)
430 MPa min
Elongation
≥17%
18 % min
Condition
Not specified
Case hardened, 19 mm test bar
Typical Applications
BS 970 EN3B
General engineering, cold forming
BS 970 (Part 1) 045A10
Case hardening steel (section four)
Key Differences
BS 970 EN3B specifies Si, S, P which are not specified for BS 970 (Part 1) 045A10.
Can BS 970 EN3B Be Substituted With BS 970 (Part 1) 045A10?
BS 970 EN3B and BS 970 (Part 1) 045A10 share some compositional similarity but differ enough that substitution should not be assumed. Review the differences above carefully, and consult the applicable standard or a metallurgist before using one in place of the other.
What is the difference between BS 970 EN3B and BS 970 (Part 1) 045A10?
BS 970 EN3B specifies Si, S, P which are not specified for BS 970 (Part 1) 045A10.
Can BS 970 EN3B be substituted with BS 970 (Part 1) 045A10?