EN 10025-2 S460JR vs CSA G40.21 300W

Related Material — 58.6% match based on chemical composition and mechanical property overlap.

EN 10025-2 S460JR (EN 10025-2:2019) and CSA G40.21 300W (CSA G40.21-13 (R2023)) are both steel grades. Both fall under the Structural Steel category. EN 10025-2 S460JR is typically used for hot rolled products of structural steels, while CSA G40.21 300W is commonly used for structural fabrication,bridges,buildings,machinery frames,general construction,welded structures. EN 10025-2 S460JR is defined under European Standard (EN), originating from Europe, while CSA G40.21 300W is defined under Canadian Standards Association (CSA), originating from Canada.

As per chemical composition, EN 10025-2 S460JR vs CSA G40.21 300W is a 83.6% match. As per mechanical properties, the match is 8.6%. Combined, this makes them a related material overall at 58.6%.

Frequently Compared With EN 10025-2 S460JR:
CSA G40.21 260W CSA G40.21 400W CSA G40.21 480W ASTM A1008 SS Grade 80 ASTM A572 Gr.65
Other Structural Steel Grades to Compare With EN 10025-2 S460JR:
GOST 19281 09G2S AS/NZS 3679.1 300 AS/NZS 3679.1 350 CSA G40.21 350W CSA G40.21 400A ASTM A1008 SS Grade 50 ASTM A283C
Match Breakdown
CHEMISTRY MATCH
83.6%
MECHANICAL MATCH
8.6%
OVERALL
58.6%
Specifications
Property EN 10025-2 S460JR CSA G40.21 300W
Standard EN 10025-2:2019 CSA G40.21-13 (R2023)
Category Structural Steel Structural Steel
C (%) <=0.20 <=0.23
Si (%) <=0.55 Not specified
Mn (%) <=1.70 <=1.50
P (%) <=0.030 <=0.040
S (%) <=0.030 <=0.050
N (%) <=0.025 Not specified
Cu (%) <=0.55 Not specified
Nb (%) <=0.05 Not specified
V (%) <=0.13 Not specified
Ti (%) <=0.05 Not specified
Matched by chemical composition and mechanical properties, not a formal equivalence claim. Always verify against the applicable standard before substitution.
Mechanical Properties
Property EN 10025-2 S460JR CSA G40.21 300W
Tensile Strength 550-720 MPa 450-620 MPa
Yield Strength >=460 MPa 300 MPa min
Elongation >=17% 20-23 %
Condition Nominal thickness up to 16 mm (tensile for 3 to 100 mm, elongation for 3 to 40 mm), longitudinal test pieces Not specified
Typical Applications
EN 10025-2 S460JR
Hot rolled products of structural steels
CSA G40.21 300W
structural fabrication,bridges,buildings,machinery frames,general construction,welded structures
Key Differences
Can EN 10025-2 S460JR Be Substituted With CSA G40.21 300W?
EN 10025-2 S460JR and CSA G40.21 300W share some compositional similarity but differ enough that substitution should not be assumed. Review the differences above carefully, and consult the applicable standard or a metallurgist before using one in place of the other.
Forms & Sizes Available on M-EX
EN 10025-2 S460JR
No active listings currently.
CSA G40.21 300W
Plate → (2 listings)
Thickness: 10–10 mm (0.39–0.39 in)
Width: 1500–1500 mm (59.06–59.06 in)
Length: 2700–2800 mm (106.3–110.24 in)
On M-EX Right Now
EN 10025-2 S460JR
0 active listings and RFQs →
CSA G40.21 300W
2 active listings and RFQs →
Frequently Asked Questions
What is the difference between EN 10025-2 S460JR and CSA G40.21 300W?
EN 10025-2 S460JR specifies Si, N, Cu, Nb which are not specified for CSA G40.21 300W.
Can EN 10025-2 S460JR be substituted with CSA G40.21 300W?
EN 10025-2 S460JR and CSA G40.21 300W share some compositional similarity but differ enough that substitution should not be assumed. Review the differences above carefully, and consult the applicable standard or a metallurgist before using one in place of the other.