EN 10025-2 S500J0 vs CSA G40.21 480W

Close Alternative — 73.5% match based on chemical composition and mechanical property overlap.

EN 10025-2 S500J0 (EN 10025-2:2019) and CSA G40.21 480W (CSA G40.21-13 (R2023)) are both steel grades. Both fall under the Structural Steel category. EN 10025-2 S500J0 is typically used for hot rolled products of structural steels, while CSA G40.21 480W is commonly used for heavy cranes, offshore structures, high-rise building frames, pressure vessels, heavy mining equipment.. EN 10025-2 S500J0 is defined under European Standard (EN), originating from Europe, while CSA G40.21 480W is defined under Canadian Standards Association (CSA), originating from Canada.

As per chemical composition, EN 10025-2 S500J0 vs CSA G40.21 480W is a 90% match. As per mechanical properties, the match is 40.5%. Combined, this makes them a close alternative overall at 73.5%.

Frequently Compared With EN 10025-2 S500J0:
GOST 19281 09G2S CSA G40.21 260W AS/NZS 3679.1 300 CSA G40.21 300W AS/NZS 3679.1 350 CSA G40.21 350W CSA G40.21 400A CSA G40.21 400W ASTM A1008 SS Grade 50 ASTM A1008 SS Grade 80 ASTM A283C ASTM A572 Gr.65
Match Breakdown
CHEMISTRY MATCH
90%
MECHANICAL MATCH
40.5%
OVERALL
73.5%
Specifications
Property EN 10025-2 S500J0 CSA G40.21 480W
Standard EN 10025-2:2019 CSA G40.21-13 (R2023)
Category Structural Steel Structural Steel
C (%) <=0.20 max 0.23
Si (%) <=0.55 max 0.5
Mn (%) <=1.70 max 1.7
P (%) <=0.030 max 0.035
S (%) <=0.030 max 0.035
N (%) <=0.025 Not specified
Cu (%) <=0.55 Not specified
Nb (%) <=0.05 Not specified
V (%) <=0.13 Not specified
Ti (%) <=0.05 Not specified
Matched by chemical composition and mechanical properties, not a formal equivalence claim. Always verify against the applicable standard before substitution.
Mechanical Properties
Property EN 10025-2 S500J0 CSA G40.21 480W
Tensile Strength 580-760 MPa 590-790 MPa
Yield Strength >=500 MPa 480 MPa min
Elongation >=15% Not specified
Condition Nominal thickness up to 16 mm (tensile for 3 to 100 mm, elongation for 3 to 40 mm), longitudinal test pieces Not specified
Typical Applications
EN 10025-2 S500J0
Hot rolled products of structural steels
CSA G40.21 480W
Heavy cranes, offshore structures, high-rise building frames, pressure vessels, heavy mining equipment.
Key Differences
Can EN 10025-2 S500J0 Be Substituted With CSA G40.21 480W?
EN 10025-2 S500J0 and CSA G40.21 480W are a close alternative rather than a direct substitute. Some properties overlap well, but check the specific chemistry and mechanical rows above against your application's requirements before treating them as interchangeable.
Forms & Sizes Available on M-EX
EN 10025-2 S500J0
No active listings currently.
CSA G40.21 480W
Plate → (2 listings)
Thickness: 10–10 mm (0.39–0.39 in)
Width: 1500–1500 mm (59.06–59.06 in)
Length: 2900–3000 mm (114.17–118.11 in)
On M-EX Right Now
EN 10025-2 S500J0
0 active listings and RFQs →
CSA G40.21 480W
2 active listings and RFQs →
Frequently Asked Questions
What is the difference between EN 10025-2 S500J0 and CSA G40.21 480W?
EN 10025-2 S500J0 specifies N, Cu, Nb, V which are not specified for CSA G40.21 480W.
Can EN 10025-2 S500J0 be substituted with CSA G40.21 480W?
EN 10025-2 S500J0 and CSA G40.21 480W are a close alternative rather than a direct substitute. Some properties overlap well, but check the specific chemistry and mechanical rows above against your application's requirements before treating them as interchangeable.