EN 10083-1:1991 50CrMo4 Steel: Specifications & Listings

EN 10083-1:1991 50CrMo4: A chromium molybdenum alloy steel for quenching and tempering to EN 10083-1:1991 (printed 50 CrMo 4). Supplied as semi-finished products, bars, rod, wide flats, hot rolled strip, sheet and plate, and forgings. Quenched and tempered tensile strength 1100 to 1300 MPa for ruling sections up to 16 mm.

Category: Alloy Steel
Grade Details
GradeEN 10083-1:1991 50CrMo4
Standard EN 10083-1:1991
ApplicationsQuenched and tempered machine parts; non alloy steels also normalized (clause 1)
Equivalent / Similar Grades
Grade Standard Region Live on M-EX
ISO 50 CrMo 4 ISO 683-1:1987 International Not yet on M-EX
DIN 50 CrMo 4 (1.7228) DIN Germany Not yet on M-EX
BS 708M50 BS UK Not yet on M-EX
Grade ComparisonCompare With a Specific Grade →
Grade Standard Match
EN 10083-1 50CrMo4 EN 10083-1:1996 Strong Match
EN 10083-3 50CrMo4 EN 10083-3:2006 Strong Match
IS 1570 (Part 4) 42Cr4Mo2 IS 1570 (Part 4):1988 Close Alternative
BS 970 (Part 3) 708M40 BS 970 (Part 3):1991 Close Alternative
BS 970 (Part 1) 708A47 BS 970 (Part 1):1983 Close Alternative
SAE J404 4150 SAE J404:2009 Close Alternative
SAE J404 4150 SAE J404:2000 Close Alternative
BS 970 (Part 1) 708A37 BS 970 (Part 1):1983 Close Alternative
Matched by chemical composition and mechanical properties, not a formal equivalence claim. Always verify against the applicable standard before substitution.
Chemical Composition (%)
C Cr Mn Mo P S Si
0.46-0.54 0.90-1.20 0.50-0.80 0.15-0.30 <=0.035 <=0.035 <=0.40
Mechanical Properties
Condition Quenched and tempered, ruling section d <= 16 mm
Elongation 9% min
Hardness Soft annealed: 248 HB max
Tensile Strength 1100 to 1300 MPa
Yield Strength 900 MPa min

More data from EN 10083-1:1991

From the standard
Other composition limits Table III and its notes
Designation as printed
50 CrMo 4
Improved machinability
Steels with lead or higher sulphur, up to about 0.100% S, may be supplied on request (Table III, note 3)
Elements not quoted in Table III are not intentionally added without the purchaser's agreement, other than for finishing the heat. With hardenability requirements, slight deviations within Table IV are permitted except for carbon, phosphorus and sulphur.
Source: EN 10083-1:1991 (UNI EN 10083-1), Table III and its notes
Mechanical properties, quenched and tempered 5 sections
Ruling sectionYield strength Re, min (MPa)Tensile strength Rm (MPa)Elongation A, min (%)Reduction of area Z, min (%)Impact KV, min (J)
d <= 16 mm, t <= 8 mm9001100 to 130094030
16 mm < d <= 40 mm, 8 mm < t <= 20 mm7801000 to 1200104530
40 mm < d <= 100 mm, 20 mm < t <= 60 mm700900 to 1100125030
100 mm < d <= 160 mm, 60 mm < t <= 100 mm650850 to 1000135030
160 mm < d <= 250 mm, 100 mm < t <= 160 mm550800 to 950135030
Re is the upper yield strength or, if no yield phenomenon occurs, the 0.2% proof strength; A on gauge length 5.65 times the root of the original cross section; KV on longitudinal ISO V-notch test pieces, average of 3 values, no single value below 70% of the minimum. Ruling sections as in Appendix B. Sizes not listed are not covered by the standard. Impact values are provisional (Table IX, note 4).
Source: EN 10083-1:1991 (UNI EN 10083-1), Table IX
Maximum hardness by delivery condition Table VIII
Treated to improve shearability (TS), max
Not specified
Soft annealed (TA), max
248 HB
Values also apply to the grades with hardenability requirements (H, HH, HL); not applicable to continuously cast slabs not further deformed. Where shearability is important, order this steel soft annealed.
Source: EN 10083-1:1991 (UNI EN 10083-1), Table VIII
Hardenability, end quench test (H) Hardness band
Hardness band (HRC, minimum to maximum) by distance from the quenched end (mm)
1.5
3
5
7
9
11
13
15
20
25
30
35
40
45
50
Distance from quenched end (mm)1.5357911131520253035404550
Maximum, HRC656564646363636261605857555454
Minimum, HRC585857555453514845413938373636
Applies when ordered with the letter H. End quench test at 850 ± 5 deg C (Table XIII).
Source: EN 10083-1:1991 (UNI EN 10083-1), Table V
Restricted hardenability (HH, HL), HRC Table VII
Limit1.5 mm3 mm5 mm7 mm9 mm11 mm13 mm15 mm20 mm25 mm30 mm35 mm40 mm45 mm50 mm
HH max.656564646363636261605857555454
HH min.606059585756555350474544434242
HL max.636362616060595756545251494848
HL min.585857555453514845413938373636
Restricted scatter bands by distance from the quenched end.
Source: EN 10083-1:1991 (UNI EN 10083-1), Table VII
Minimum hardness of strip as quenched Table XI
Hardness, min
680 HV
Maximum strip thickness
3 mm
Applies to the quenching temperatures of Table XIII with oil cooling.
Source: EN 10083-1:1991 (UNI EN 10083-1), Table XI
Heat treatment Table XIII
Quenching
820 to 860 deg C
Quenching agent
Oil
Tempering
540 to 680 deg C
End quench test
850 ± 5 deg C
Guidance values except the end quench test temperature, which is binding. Lower quenching temperatures generally for water, upper for oil; austenitizing at least 30 min, tempering at least 60 min (guide values).
Source: EN 10083-1:1991 (UNI EN 10083-1), Table XIII

Active EN 10083-1:1991 50CrMo4 Listings on M-EX (For Sale)

+ Create a Listing for this grade

No active EN 10083-1:1991 50CrMo4 listings at this time.

Register for Alerts

Buyer RFQs for EN 10083-1:1991 50CrMo4

+ Post an RFQ for this grade

No open buyer requirements for EN 10083-1:1991 50CrMo4 at this time.

Register for Alerts