Related Material — 69.9% match
based on chemical composition and mechanical property overlap.
IS 5517 40Ni14 (IS 5517:1993) and EN 10084 15NiCr13 (EN 10084:2008) are both steel grades.
Both fall under the Alloy Steel category.
IS 5517 40Ni14 is defined under Bureau of Indian Standards (IS), originating from India, while EN 10084 15NiCr13 is defined under European Standard (EN), originating from Europe.
As per chemical composition, IS 5517 40Ni14 vs EN 10084 15NiCr13 is a 72.8% match.
As per mechanical properties, the match is 100%.
Combined, this makes them a related material overall at 69.9%.
Matched by chemical composition and mechanical properties, not a formal equivalence claim. Always verify against the applicable standard before substitution.
Mechanical Properties
Property
IS 5517 40Ni14
EN 10084 15NiCr13
Tensile Strength
800-950 MPa
Not specified
Yield Strength (0.2% proof)
600 MPa min
Not specified
Elongation
>=16%
Not specified
Izod Impact
55 J min
Not specified
Hardness (annealed)
<=229 HB
Not specified
Condition
Hardened and tempered, ruling section up to 100 mm
Soft annealed
Hardenability
Not specified
+H band at 1.5 mm from the quenched end: 41 to 48 HRC
Hardness
Not specified
Soft annealed: 229 HB max
Typical Applications
IS 5517 40Ni14
Not documented
EN 10084 15NiCr13
Heavily loaded gears, cams, camshafts
Can IS 5517 40Ni14 Be Substituted With EN 10084 15NiCr13?
IS 5517 40Ni14 and EN 10084 15NiCr13 share some compositional similarity but differ enough that substitution should not be assumed. Review the differences above carefully, and consult the applicable standard or a metallurgist before using one in place of the other.
What is the difference between IS 5517 40Ni14 and EN 10084 15NiCr13?
Both grades share a similar composition profile; see the specification table above for the exact chemistry and mechanical property values.
Can IS 5517 40Ni14 be substituted with EN 10084 15NiCr13?
IS 5517 40Ni14 and EN 10084 15NiCr13 share some compositional similarity but differ enough that substitution should not be assumed. Review the differences above carefully, and consult the applicable standard or a metallurgist before using one in place of the other.