Minimal Match — 35% match
based on chemical composition and mechanical property overlap.
IS 6603 X02Cr25Ni7Mo4N (IS 6603:2024) and GB/T 3280 06Cr19Ni10 (GB/T 3280-2015) are both steel grades.
Both fall under the Stainless Steel category.
IS 6603 X02Cr25Ni7Mo4N is typically used for general purposes, semi-finished products, bars, wire rods and bright bars, while GB/T 3280 06Cr19Ni10 is commonly used for used for kitchen equipment, food processing machinery, chemical tanks, piping, architectural panels, and fasteners..
IS 6603 X02Cr25Ni7Mo4N is defined under Bureau of Indian Standards (IS), originating from India, while GB/T 3280 06Cr19Ni10 is defined under Guobiao Standards (GB/T), originating from China.
As per chemical composition, IS 6603 X02Cr25Ni7Mo4N vs GB/T 3280 06Cr19Ni10 is a 62.2% match.
As per mechanical properties, the match is 0%.
Combined, this makes them a minimal match overall at 35%.
Matched by chemical composition and mechanical properties, not a formal equivalence claim. Always verify against the applicable standard before substitution.
Mechanical Properties
Property
IS 6603 X02Cr25Ni7Mo4N
GB/T 3280 06Cr19Ni10
Tensile Strength
>=730 MPa
520-720 MPa
Yield Strength
>=530 MPa
205-310 MPa
Elongation
>=25%
40-60%
Hardness
<=290 HB
187 HB max
Condition
Solution annealed, conditions 1C, 1E, 1D, 1X, 1G and 2D, thickness or diameter up to 160 mm; Tensile Strength is a minimum as printed, hardness for guidance only
Not specified
Typical Applications
IS 6603 X02Cr25Ni7Mo4N
General purposes, semi-finished products, bars, wire rods and bright bars
GB/T 3280 06Cr19Ni10
Used for kitchen equipment, food processing machinery, chemical tanks, piping, architectural panels, and fasteners.
Key Differences
IS 6603 X02Cr25Ni7Mo4N specifies Mo, N which are not specified for GB/T 3280 06Cr19Ni10.
Can IS 6603 X02Cr25Ni7Mo4N Be Substituted With GB/T 3280 06Cr19Ni10?
IS 6603 X02Cr25Ni7Mo4N and GB/T 3280 06Cr19Ni10 share some compositional similarity but differ enough that substitution should not be assumed. Review the differences above carefully, and consult the applicable standard or a metallurgist before using one in place of the other.
What is the difference between IS 6603 X02Cr25Ni7Mo4N and GB/T 3280 06Cr19Ni10?
IS 6603 X02Cr25Ni7Mo4N specifies Mo, N which are not specified for GB/T 3280 06Cr19Ni10.
Can IS 6603 X02Cr25Ni7Mo4N be substituted with GB/T 3280 06Cr19Ni10?
IS 6603 X02Cr25Ni7Mo4N and GB/T 3280 06Cr19Ni10 share some compositional similarity but differ enough that substitution should not be assumed. Review the differences above carefully, and consult the applicable standard or a metallurgist before using one in place of the other.