Market Intelligence  ›  Price Gap  ›  BS 970 EN3A

BS 970 EN3A Steel: Price Gap

Demand price (median buyer ceiling from RFQs) versus offer price (median seller reserve from listings), and the gap between them, for BS 970 EN3A across India. Click a region to drill into states.

Live Signal Lifetime
Lifetime: The gap between buyer bids and seller asks, across everything ever listed on M-EX. Use this for the long view. For example, “Has this grade usually traded with buyers bidding above sellers?”
Viewing a specific grade. Switch grade:
Clear ×
Market direction
Buyers bidding higher
Price gap (National)
+Rs. 7,736
Current
+Rs. 7,736
17 RFQs · 69 listings
7 days ago
+Rs. 7,736
Buyers were willing to pay the same as today
17 RFQs · 69 listings
15 days ago
+Rs. 7,744
Buyers were willing to pay Rs. 8 more than today
17 RFQs · 66 listings
30 days ago
+Rs. 7,747
Buyers were willing to pay Rs. 11 more than today
16 RFQs · 65 listings
This gap is narrower than typical for Carbon Steel nationally (14.5% vs a 22.2% category average).
Direction has held at “buyers bidding higher” for 124 days.
Demand above offer (positive gap)
Offer above demand (negative gap)
Insufficient data (< 3 each side)
See activity (demand & supply) across India ›

Disclaimer: All information on this page is indicative only and derived from posted listings and RFQs on M-EX. It does not constitute a market price quote or investment advice. M-EX and GTE make no representations as to accuracy or completeness. Actual activity depends on quantity, quality, payment terms and other commercial factors agreed between buyers and sellers.

BS 970 EN3A is a Carbon Steel grade: EN3A: 20 carbon steel (hot rolled or normalised). Specified in BS 970:1955, Part 2. Typical applications: Bolts, screws, light structural components.
Equivalent / Similar Grades (4)
Grade Standard Region
AISI 1020 SAE USA
SAE1020 SAE USA
S20C JIS Japan
070M20 BS 970 (Part 1) UK
Chemical Composition (%)
C Si Mn S P
0.15-0.25 0.05-0.35 0.40-0.90 <=0.060 <=0.060
Mechanical Properties
Tensile Strength ≥432 MPa (28 tons/sq in, converted)
Elongation ≥25%
Condition , ruling section 6 in (lowest-strength condition of the standard)