Related Material — 68.3% match
based on chemical composition and mechanical property overlap.
EN 10025-3 S500 (EN 10025-3:2019) and ASTM A572 Gr.65 (ASTM A572) are both steel grades.
Both fall under the Structural Steel category.
EN 10025-3 S500 is typically used for used in heavy structural sections, mining equipment, bridge fabrication, transport vehicles, and offshore structures., while ASTM A572 Gr.65 is commonly used for used for bridges, buildings, transmission towers, construction equipment, offshore structures, and structural members..
EN 10025-3 S500 is defined under European Standard (EN), originating from Europe, while ASTM A572 Gr.65 is defined under ASTM International, originating from United States.
As per chemical composition, EN 10025-3 S500 vs ASTM A572 Gr.65 is a 91.4% match.
As per mechanical properties, the match is 22.1%.
Combined, this makes them a related material overall at 68.3%.
Matched by chemical composition and mechanical properties, not a formal equivalence claim. Always verify against the applicable standard before substitution.
Mechanical Properties
Property
EN 10025-3 S500
ASTM A572 Gr.65
Tensile Strength
590-770 MPa
550-690 MPa
Yield Strength
500 MPa min
450 MPa min
Elongation
16% min
18-21%
Hardness
190-240 HB
170-220 HB
Typical Applications
EN 10025-3 S500
Used in heavy structural sections, mining equipment, bridge fabrication, transport vehicles, and offshore structures.
ASTM A572 Gr.65
Used for bridges, buildings, transmission towers, construction equipment, offshore structures, and structural members.
Key Differences
EN 10025-3 S500 specifies Ti which is not specified for ASTM A572 Gr.65.
Can EN 10025-3 S500 Be Substituted With ASTM A572 Gr.65?
EN 10025-3 S500 and ASTM A572 Gr.65 share some compositional similarity but differ enough that substitution should not be assumed. Review the differences above carefully, and consult the applicable standard or a metallurgist before using one in place of the other.
What is the difference between EN 10025-3 S500 and ASTM A572 Gr.65?
EN 10025-3 S500 specifies Ti which is not specified for ASTM A572 Gr.65.
Can EN 10025-3 S500 be substituted with ASTM A572 Gr.65?
EN 10025-3 S500 and ASTM A572 Gr.65 share some compositional similarity but differ enough that substitution should not be assumed. Review the differences above carefully, and consult the applicable standard or a metallurgist before using one in place of the other.