Strong Match — 88.9% match
based on chemical composition and mechanical property overlap.
EN 10346 S350GD (EN 10346:2015) and AS/NZS 1595 C350 (AS/NZS 1595:1998) are both steel grades.
Both fall under the Structural Steel category.
EN 10346 S350GD is typically used for continuous hot-dip galvanized structural steel strip/sheet; roll-formed and cold-formed structural sections, purlins, roofing and cladding requiring corrosion protection, while AS/NZS 1595 C350 is commonly used for cold-rolled structural steel sheet; roll-forming, cold-formed structural sections, purlins.
EN 10346 S350GD is defined under European Standard (EN), originating from Europe, while AS/NZS 1595 C350 is defined under Australian/New Zealand Standard (AS/NZS), originating from Australia/New Zealand.
As per chemical composition, EN 10346 S350GD vs AS/NZS 1595 C350 is a 100% match.
As per mechanical properties, the match is 66.7%.
Combined, this makes them a strong match overall at 88.9%.
Matched by chemical composition and mechanical properties, not a formal equivalence claim. Always verify against the applicable standard before substitution.
Mechanical Properties
Property
EN 10346 S350GD
AS/NZS 1595 C350
Tensile Strength
420 MPa min
430 MPa min
Yield Strength
350 MPa min
350 MPa min
Elongation
14% min
14% min
Typical Applications
EN 10346 S350GD
Continuous hot-dip galvanized structural steel strip/sheet; roll-formed and cold-formed structural sections, purlins, roofing and cladding requiring corrosion protection
Can EN 10346 S350GD Be Substituted With AS/NZS 1595 C350?
EN 10346 S350GD and AS/NZS 1595 C350 overlap closely enough on chemistry and mechanical properties that AS/NZS 1595 C350 is often considered as a substitute for EN 10346 S350GD in many applications. Always confirm the specific property range your application needs before substituting, and check with your supplier's mill certificate.
What is the difference between EN 10346 S350GD and AS/NZS 1595 C350?
Both grades share a similar composition profile; see the specification table above for the exact chemistry and mechanical property values.
Can EN 10346 S350GD be substituted with AS/NZS 1595 C350?
EN 10346 S350GD and AS/NZS 1595 C350 overlap closely enough on chemistry and mechanical properties that AS/NZS 1595 C350 is often considered as a substitute for EN 10346 S350GD in many applications. Always confirm the specific property range your application needs before substituting, and check with your supplier's mill certificate.