IS 11169 (Part 2) X02Cr17Ni12Mo2 vs ASTM A959 316LN
Strong Match — 92.4% match
based on chemical composition and mechanical property overlap.
IS 11169 (Part 2) X02Cr17Ni12Mo2 (IS 11169 (Part 2):1989) and ASTM A959 316LN (ASTM A959:2011) are both steel grades.
Both fall under the Stainless Steel category.
IS 11169 (Part 2) X02Cr17Ni12Mo2 is typically used for cold heading and cold extrusion; the standard covers wires, wire rods and bars (clause 1.1), while ASTM A959 316LN is commonly used for wrought stainless steel products; recommended composition limits for adoption by product standards (clause 1.1).
IS 11169 (Part 2) X02Cr17Ni12Mo2 is defined under Bureau of Indian Standards (IS), originating from India, while ASTM A959 316LN is defined under ASTM International, originating from United States.
As per chemical composition, IS 11169 (Part 2) X02Cr17Ni12Mo2 vs ASTM A959 316LN is a 92.4% match.
Mechanical property data is not available for both grades, so this factor could not be scored.
Combined, this makes them a strong match overall at 92.4%.
Frequently Compared With IS 11169 (Part 2) X02Cr17Ni12Mo2:
Matched by chemical composition and mechanical properties, not a formal equivalence claim. Always verify against the applicable standard before substitution.
Mechanical Properties
Property
IS 11169 (Part 2) X02Cr17Ni12Mo2
ASTM A959 316LN
Yield Strength (0.2% proof)
>=225 MPa
Not specified
Tensile Strength
500-750 MPa
Not specified
Elongation
>=40%
Not specified
Impact (U-notch 5 mm)
>=60 J
Not specified
Condition
Quenched reference test piece (Table 6 treatment)
Not specified
Typical Applications
IS 11169 (Part 2) X02Cr17Ni12Mo2
Cold heading and cold extrusion; the standard covers wires, wire rods and bars (clause 1.1)
ASTM A959 316LN
Wrought stainless steel products; recommended composition limits for adoption by product standards (clause 1.1)
Key Differences
ASTM A959 316LN specifies N which is not specified for IS 11169 (Part 2) X02Cr17Ni12Mo2.
Can IS 11169 (Part 2) X02Cr17Ni12Mo2 Be Substituted With ASTM A959 316LN?
IS 11169 (Part 2) X02Cr17Ni12Mo2 and ASTM A959 316LN overlap closely enough on chemistry and mechanical properties that ASTM A959 316LN is often considered as a substitute for IS 11169 (Part 2) X02Cr17Ni12Mo2 in many applications. Always confirm the specific property range your application needs before substituting, and check with your supplier's mill certificate.
What is the difference between IS 11169 (Part 2) X02Cr17Ni12Mo2 and ASTM A959 316LN?
ASTM A959 316LN specifies N which is not specified for IS 11169 (Part 2) X02Cr17Ni12Mo2.
Can IS 11169 (Part 2) X02Cr17Ni12Mo2 be substituted with ASTM A959 316LN?
IS 11169 (Part 2) X02Cr17Ni12Mo2 and ASTM A959 316LN overlap closely enough on chemistry and mechanical properties that ASTM A959 316LN is often considered as a substitute for IS 11169 (Part 2) X02Cr17Ni12Mo2 in many applications. Always confirm the specific property range your application needs before substituting, and check with your supplier's mill certificate.