IS 2062 (Part 1) E235B0 vs CSA G40.21 260W

Related Material — 65.1% match based on chemical composition and mechanical property overlap.

IS 2062 (Part 1) E235B0 (IS 2062 (Part 1):2025) and CSA G40.21 260W (CSA G40.21-13 (R2023)) are both steel grades. Both fall under the Structural Steel category. IS 2062 (Part 1) E235B0 is typically used for structural work: welded, bolted and riveted structures and general engineering purposes, while CSA G40.21 260W is commonly used for bridges, buildings, general structural fabrication, storage tanks, older infrastructure projects.. IS 2062 (Part 1) E235B0 is defined under Bureau of Indian Standards (IS), originating from India, while CSA G40.21 260W is defined under Canadian Standards Association (CSA), originating from Canada.

As per chemical composition, IS 2062 (Part 1) E235B0 vs CSA G40.21 260W is a 97.6% match. As per mechanical properties, the match is 0%. Combined, this makes them a related material overall at 65.1%.

Frequently Compared With IS 2062 (Part 1) E235B0:
IS 2062 (Part 1) E235C IS 2062 (Part 1) E235BR IS 2062 (Part 1) E235A AS/NZS 3679.1 300 CSA G40.21 400A CSA G40.21 400W CSA G40.21 300W AS/NZS 3679.1 350 CSA G40.21 350W CSA G40.21 480W ASTM A1008 SS Grade 50 GOST 19281 09G2S
Match Breakdown
CHEMISTRY MATCH
97.6%
MECHANICAL MATCH
0%
OVERALL
65.1%
Specifications
Property IS 2062 (Part 1) E235B0 CSA G40.21 260W
Standard IS 2062 (Part 1):2025 CSA G40.21-13 (R2023)
Category Structural Steel Structural Steel
C (%) <=0.20 max 0.23
Mn (%) <=1.40 max 1.4
Si (%) <=0.40 max 0.4
S (%) <=0.045 max 0.035
P (%) <=0.045 max 0.035
CEV (%) <=0.39 Not specified
Matched by chemical composition and mechanical properties, not a formal equivalence claim. Always verify against the applicable standard before substitution.
Mechanical Properties
Property IS 2062 (Part 1) E235B0 CSA G40.21 260W
Tensile Strength >=360 MPa 410-590 MPa
Yield Strength 235 MPa (<=16mm) / 225 MPa (16-40mm) / 215 MPa (40-100mm) / 195 MPa (>100mm) 260 MPa min
Elongation >=26% (<=40mm) / >=25% (40-63mm) / >=24% (63-100mm) / >=22% (>100mm) Not specified
Impact Energy >=27 J at 0°C Not specified
Typical Applications
IS 2062 (Part 1) E235B0
Structural work: welded, bolted and riveted structures and general engineering purposes
CSA G40.21 260W
Bridges, buildings, general structural fabrication, storage tanks, older infrastructure projects.
Key Differences
Can IS 2062 (Part 1) E235B0 Be Substituted With CSA G40.21 260W?
IS 2062 (Part 1) E235B0 and CSA G40.21 260W share some compositional similarity but differ enough that substitution should not be assumed. Review the differences above carefully, and consult the applicable standard or a metallurgist before using one in place of the other.
Forms & Sizes Available on M-EX
IS 2062 (Part 1) E235B0
No active listings currently.
CSA G40.21 260W
Plate → (2 listings)
Thickness: 10–10 mm (0.39–0.39 in)
Width: 1500–1500 mm (59.06–59.06 in)
Length: 3400–4000 mm (133.86–157.48 in)
On M-EX Right Now
IS 2062 (Part 1) E235B0
0 active listings and RFQs →
CSA G40.21 260W
2 active listings and RFQs →
Frequently Asked Questions
What is the difference between IS 2062 (Part 1) E235B0 and CSA G40.21 260W?
IS 2062 (Part 1) E235B0 specifies CEV which is not specified for CSA G40.21 260W.
Can IS 2062 (Part 1) E235B0 be substituted with CSA G40.21 260W?
IS 2062 (Part 1) E235B0 and CSA G40.21 260W share some compositional similarity but differ enough that substitution should not be assumed. Review the differences above carefully, and consult the applicable standard or a metallurgist before using one in place of the other.