Related Material — 67.9% match
based on chemical composition and mechanical property overlap.
CSA G40.21 350W (CSA G40.21-13 (R2023)) and ASTM A572 Grade 50 (ASTM A572) are both steel grades.
Both fall under the Structural Steel category.
CSA G40.21 350W is typically used for used in buildings, bridges, cranes, transmission towers, heavy equipment, and structural fabrications., while ASTM A572 Grade 50 is commonly used for high-strength low-alloy structural steel; buildings, bridges, transmission towers, construction equipment, general structural fabrication.
CSA G40.21 350W is defined under Canadian Standards Association (CSA), originating from Canada, while ASTM A572 Grade 50 is defined under ASTM International, originating from United States.
As per chemical composition, CSA G40.21 350W vs ASTM A572 Grade 50 is a 91.6% match.
As per mechanical properties, the match is 20.7%.
Combined, this makes them a related material overall at 67.9%.
Matched by chemical composition and mechanical properties, not a formal equivalence claim. Always verify against the applicable standard before substitution.
Mechanical Properties
Property
CSA G40.21 350W
ASTM A572 Grade 50
Tensile Strength
450-620 MPa
450 MPa min
Yield Strength
350 MPa min
345 MPa min
Elongation
20% min
18% min
Hardness
135-180 HB
137-187 HB
Typical Applications
CSA G40.21 350W
Used in buildings, bridges, cranes, transmission towers, heavy equipment, and structural fabrications.
ASTM A572 Grade 50
High-strength low-alloy structural steel; buildings, bridges, transmission towers, construction equipment, general structural fabrication
Key Differences
ASTM A572 Grade 50 specifies Nb, V which are not specified for CSA G40.21 350W.
Can CSA G40.21 350W Be Substituted With ASTM A572 Grade 50?
CSA G40.21 350W and ASTM A572 Grade 50 share some compositional similarity but differ enough that substitution should not be assumed. Review the differences above carefully, and consult the applicable standard or a metallurgist before using one in place of the other.
What is the difference between CSA G40.21 350W and ASTM A572 Grade 50?
ASTM A572 Grade 50 specifies Nb, V which are not specified for CSA G40.21 350W.
Can CSA G40.21 350W be substituted with ASTM A572 Grade 50?
CSA G40.21 350W and ASTM A572 Grade 50 share some compositional similarity but differ enough that substitution should not be assumed. Review the differences above carefully, and consult the applicable standard or a metallurgist before using one in place of the other.