IS 11169 (Part 2) X04Cr18Ni10Ti vs GOST 5632 08X18H10

Minimal Match — 35% match based on chemical composition and mechanical property overlap.

IS 11169 (Part 2) X04Cr18Ni10Ti (IS 11169 (Part 2):2023) and GOST 5632 08X18H10 (GOST 5632-2014) are both steel grades. Both fall under the Stainless Steel category. IS 11169 (Part 2) X04Cr18Ni10Ti is typically used for cold heading and cold extrusion of stainless steel parts; the standard covers wires, wire rods and bars of 0.8 to 50 mm (clause 1.1, table 11), while GOST 5632 08X18H10 is commonly used for chemical equipment, food processing, general corrosion resistant applications. IS 11169 (Part 2) X04Cr18Ni10Ti is defined under Bureau of Indian Standards (IS) (India).

As per chemical composition, IS 11169 (Part 2) X04Cr18Ni10Ti vs GOST 5632 08X18H10 is a 79.4% match. As per mechanical properties, the match is 0%. Combined, this makes them a minimal match overall at 35%.

Frequently Compared With IS 11169 (Part 2) X04Cr18Ni10Ti:
EN 10088-1 1.4301 IS 1570 (Part 7) 12Cr12Ni2Mo IS 1570 (Part 7) 12Cr13H EN 10088-1 1.4006 EN 10088-1 1.4845 IS 1570 (Part 7) 11Cr17Ni13W3TiH IS 1570 (Part 7) 12Cr12MoH IS 1570 (Part 7) 12Cr12MoVH GB/T 3280 06Cr19Ni10 GOST 5632 06Kh23N28 EN 10088-1 1.4401 GOST 5632 12Kh13
Match Breakdown
CHEMISTRY MATCH
79.4%
MECHANICAL MATCH
0%
OVERALL
35%
Specifications
Property IS 11169 (Part 2) X04Cr18Ni10Ti GOST 5632 08X18H10
Standard IS 11169 (Part 2):2023 GOST 5632-2014
Category Stainless Steel Stainless Steel
C (%) <=0.08 ≤0.08
Cr (%) 17.0-19.0 17.0–19.0
Cu (%) <=1.00 Not specified
Mn (%) <=2.00 ≤2.00
Ni (%) 9.0-12.0 9.0–11.0
P (%) <=0.045 ≤0.035
S (%) <=0.030 ≤0.020
Si (%) <=1.00 ≤0.80
Ti (%) 5xC-0.70 Not specified
Matched by chemical composition and mechanical properties, not a formal equivalence claim. Always verify against the applicable standard before substitution.
Mechanical Properties
Property IS 11169 (Part 2) X04Cr18Ni10Ti GOST 5632 08X18H10
Reduction of Area, solution annealed (+AT) >=65% (over 5 to 50 mm) Not specified
Tensile Strength, solution annealed (+AT) <=680 MPa (over 5 to 50 mm) Not specified
Tensile Strength Not specified ≥520 MPa
Yield Strength Not specified ≥205 MPa
Elongation Not specified ≥40%
Typical Applications
IS 11169 (Part 2) X04Cr18Ni10Ti
Cold heading and cold extrusion of stainless steel parts; the standard covers wires, wire rods and bars of 0.8 to 50 mm (clause 1.1, Table 11)
GOST 5632 08X18H10
Chemical equipment, food processing, general corrosion resistant applications
Key Differences
Can IS 11169 (Part 2) X04Cr18Ni10Ti Be Substituted With GOST 5632 08X18H10?
IS 11169 (Part 2) X04Cr18Ni10Ti and GOST 5632 08X18H10 share some compositional similarity but differ enough that substitution should not be assumed. Review the differences above carefully, and consult the applicable standard or a metallurgist before using one in place of the other.
Forms & Sizes Available on M-EX
IS 11169 (Part 2) X04Cr18Ni10Ti
No active listings currently.
GOST 5632 08X18H10
Sheet → (2 listings)
Thickness: 6–6 mm (0.24–0.24 in)
Width: 1250–1250 mm (49.21–49.21 in)
Length: 2500–2700 mm (98.43–106.3 in)
On M-EX Right Now
IS 11169 (Part 2) X04Cr18Ni10Ti
0 active listings and RFQs →
GOST 5632 08X18H10
2 active listings and RFQs →
Frequently Asked Questions
What is the difference between IS 11169 (Part 2) X04Cr18Ni10Ti and GOST 5632 08X18H10?
IS 11169 (Part 2) X04Cr18Ni10Ti specifies Cu, Ti which are not specified for GOST 5632 08X18H10.
Can IS 11169 (Part 2) X04Cr18Ni10Ti be substituted with GOST 5632 08X18H10?
IS 11169 (Part 2) X04Cr18Ni10Ti and GOST 5632 08X18H10 share some compositional similarity but differ enough that substitution should not be assumed. Review the differences above carefully, and consult the applicable standard or a metallurgist before using one in place of the other.