Related Material — 69.9% match
based on chemical composition and mechanical property overlap.
IS 4367 07Cr4Mo6 (IS 4367:1991) and IS 1570 (Part 4) 10Cr20Mo6 (IS 1570 (Part 4):1988) are both steel grades.
Both fall under the Alloy Steel category.
IS 4367 07Cr4Mo6 is defined under Bureau of Indian Standards (IS), originating from India, while IS 1570 (Part 4) 10Cr20Mo6 is defined under Bureau of Indian Standards (IS), originating from India.
As per chemical composition, IS 4367 07Cr4Mo6 vs IS 1570 (Part 4) 10Cr20Mo6 is a 85.6% match.
Mechanical property data is not available for both grades, so this factor could not be scored.
Combined, this makes them a related material overall at 69.9%.
Matched by chemical composition and mechanical properties, not a formal equivalence claim. Always verify against the applicable standard before substitution.
Mechanical Properties
Property
IS 4367 07Cr4Mo6
IS 1570 (Part 4) 10Cr20Mo6
Tensile Strength
380-550 MPa
Not specified
Yield Strength
225 MPa min
Not specified
Elongation
>=19%
Not specified
Izod Impact
60 J min
Not specified
Hardness (soft annealed)
<=170 HB
Not specified
Condition
Normalised and tempered, ruling section up to 40 mm
Not specified
Key Differences
IS 4367 07Cr4Mo6 specifies S, P which are not specified for IS 1570 (Part 4) 10Cr20Mo6.
Can IS 4367 07Cr4Mo6 Be Substituted With IS 1570 (Part 4) 10Cr20Mo6?
IS 4367 07Cr4Mo6 and IS 1570 (Part 4) 10Cr20Mo6 share some compositional similarity but differ enough that substitution should not be assumed. Review the differences above carefully, and consult the applicable standard or a metallurgist before using one in place of the other.
What is the difference between IS 4367 07Cr4Mo6 and IS 1570 (Part 4) 10Cr20Mo6?
IS 4367 07Cr4Mo6 specifies S, P which are not specified for IS 1570 (Part 4) 10Cr20Mo6.
Can IS 4367 07Cr4Mo6 be substituted with IS 1570 (Part 4) 10Cr20Mo6?
IS 4367 07Cr4Mo6 and IS 1570 (Part 4) 10Cr20Mo6 share some compositional similarity but differ enough that substitution should not be assumed. Review the differences above carefully, and consult the applicable standard or a metallurgist before using one in place of the other.